JIS C3410 Common Screened Shipboard Telephone Cable

PRODUCT CENTER

CATEGORIES

Page view:

JIS C3410 Common Screened Shipboard Telephone Cable

没有此类产品
description

JIS C3410 Common Screened ShipboardTelephone Cable

 

JIS C3410 Common Screened ShipboardTelephone Cable Application

JIS C 3410 Overall shield telephone cable is intended for Instrument circuit up to 250V, instrument safe systems.Fixed installation for instrument, communication, control and alarm system in both explosion risk and safe areas, general purposes.

 

JIS C 3410 CommonScreened Shipboardtelephone cable model:

250V TTYS, FA- TTYS
250V TTYCS, FA- TTYCS
250V TTYCYS, FA- TTYCYS

 

JIS C 3410 Common Screened Shipboard telephone cable Standards:

– Design guide : JIS C 3410(1999/2010)
– Flame retardant :IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
– Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
– Max. conductor temperature : 60

 

JIS C 3410 Common Screened Shipboard telephone cable Constructions:

Classification Code Construction details
Conductor TT Tinned Copper Wire JIS C3410
Insulation Y PVC as per JIS C 3410
Common Shield S Tinned Copper Wire
Armor C Galvanized steel wire braided
  CB Tinned copper wire braided
Paint   The white paint should be painted uniformly
Covering Y PVC as per JIS C 3410
    Color: Black

Recommendations:

Minimum cable bending radius
The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than :
6 times the external diameter of cable
Cable which are subjected to movements by expansion and the high voltage cable are to be bent to a form of at least 12 times cable diameter.
Installations temperature
Minimum recommended temperature of installations :
-10°C Ship wiring cable with PVC sheath
-20°C Elastomeric on/off shore cables
Installations pulling force
The cable pulling force can be estimated, as a maximum limit :5Kp per mm2 conductor area in the cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.

 

Specifications:

Cores:1, 2, 3, 4, 5, 7, 10, 12, 14, 16,19, 24, 27, 30, 33, 37.

Nominal Cross-section Areas:1 mm2, 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2,

35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2.

 

Certificates:

CCS,LR,ABS,DNV,BV,GL,NK,RINA; 90℃

 